RCD keeps tripping: how to find the cause
An RCD (residual current device, in Dutch: aardlekschakelaar) switches off as soon as current 'leaks' away, for example through a faulty appliance or moisture. That is exactly its job: it protects you against an electric shock. The trick is to find where the leak is. You can often do that yourself in a few minutes.
Never hold an RCD up by hand and never tape it in place. Then your protection no longer works and you risk an electric shock or fire.
How to find the appliance
Unplug everything
On the circuits behind that RCD (often the kitchen, bathroom or utility room). Also switch off fixed appliances such as a close-in water heater or hob if possible.
Switch the RCD up once
Does it stay up now? Then the fault is in an appliance. Does it trip even without appliances? Then go to step 4.
Plug the appliances back in one by one
Wait a moment each time. If the RCD trips with a particular appliance, you have found the culprit. Don't use that appliance again until it has been checked or replaced.
Does it trip without any appliances?
Then the fault is in the installation itself: moisture in an (outdoor) socket or junction box, a damaged cable or a worn RCD. Don't keep switching it back on, call us. We test each circuit to find where the leak is.
Never work on the fuse box or live wiring yourself. Switching a breaker up or down and unplugging appliances is safe; leave all other repairs to a certified electrician.
The most common culprits
Kettle, oven or dishwasher
Heating elements start to leak after years of use. A classic cause.
Washing machine and dryer
Especially if the RCD trips while washing or spinning.
Outdoor socket or garden lighting
Moisture after rain. Does the RCD mainly trip in wet weather? Then this is often the cause.
An old RCD
RCDs wear out too. Old ones sometimes trip for no reason.
Not working? Clear emergency rates
No inflated rates or nasty surprises: we work with fixed, fair rates. You always speak directly to our own electrician, never a call centre.
Daytime
Mon–Fri 08:00–18:00. Then € 22.50 per quarter hour.
Evening
Mon–Fri 18:00–22:00. Then € 30.00 per quarter hour.
Night & weekend
22:00–08:00, all day Saturday, Sunday and public holidays. Then € 36.25 per quarter hour.
All prices include 21% VAT and fault diagnosis. More work or a part needed? You hear the price first and you decide.
Within the municipality of Utrecht the call-out charge is € 0. Outside it we charge a fixed € 0.40 per km. A site visit costs € 90, which we deduct in full if you go ahead with the job.
Frequently asked questions
Can't sort it out? We come straight away.