PERILEX / COOKING CIRCUIT UTRECHT € 120 all-in, fixed price upfront

Perilex Connection & Cooking Circuit Installation in Utrecht

Switching to induction or getting a new cooker? INO safely connects your Perilex socket (the special Dutch socket for cookers and hobs) or cooking circuit in line with NEN 1010, with a fixed price you know before we start.

Professional Perilex connection for an induction hob by an electrician in Utrecht
Fixed all-in price: € 120 · NEN 1010

What does a Perilex connection cost? Fixed package prices

Safe installation following the manufacturer's instructions and NEN 1010, with a test report.

Connect a Perilex plug

€ 120

All-in fixed price

Only connecting the Perilex plug and the appliance (induction hob or cooker) to an existing, working Perilex wall socket.

  • ✓ Connection & phases tested
  • ✓ Perilex plug fitted
  • ✓ Connected according to the manufacturer's diagram (two-phase or three-phase)
  • ✓ Tested at full power & handed over
  • ✓ Guarantee on the installation
Request

Perilex cable & circuit installation

from € 150

From the meter cupboard

A complete Perilex cable run from the fuse box to the kitchen or attic (for an induction hob or mechanical ventilation).

  • ✓ Cable pulled (through an empty conduit)
  • ✓ Perilex wall socket fitted
  • ✓ Suitable for induction or mechanical ventilation
  • ✓ Connection in the meter cupboard / cooking circuit
  • ✓ Testing and NEN 1010 completion check

The price depends on the cable length and whether the RCD/circuit is already in the fuse box. Feel free to send a photo!

Request

Site visit?

€ 90

Fully deducted if you go ahead

Would you like us to come and look at the cable route, wall openings and fuse box first? We visit for € 90, which we deduct 100% when we carry out the job.

Request a site visit

Prices include VAT and apply to the standard situations described. For different work, you always receive a price proposal upfront.

Which connection do you need?

Hob power ratingConnection needed
up to 3.7 kWOwn cooking circuit 230 V, 16 A
3.7 – 7.4 kWPerilex two-phase, 400 V
7.4 – 11 kWPerilex three-phase, 400 V
over 11 kW / cooker with ovenPerilex three-phase + own circuit

A guide only. Always follow the rating plate and connection diagram from the manufacturer; we check this at your home.

PERILEX

Two-phase or three-phase?

With two-phase (cooking circuit 2x230V) we spread the power over two phases, which is enough for most induction hobs up to 7.4 kW. With three-phase (400V) we spread the load over three phases for heavy hobs and cookers with an oven.

Not sure whether your connection is suitable, or want to combine induction with an EV charger? Also see our fuse box options →.

HOW INO GOES ABOUT IT

From check to safe cooking.

01

Check the connection

We look at your fuse box, the space available and the connection diagram of your hob or cooker.

02

Install cable and circuit

If needed, we install a new cooking circuit and run the cable to the kitchen.

03

Fit the Perilex

We fit the Perilex socket or fixed connection and connect your appliance.

04

Test and hand over

We test the connection, leave everything tidy and give a guarantee on the work.

FREQUENTLY ASKED QUESTIONS

Perilex and cooking circuits, explained.

€ 120 all-in with an existing, suitable circuit. If a new cooking circuit needs to be installed from the meter cupboard to a Perilex socket, it costs from € 150. Both including VAT, materials and a guarantee on the work.
With two-phase we spread the power over two phases, which is enough for most induction hobs. With three-phase the load is spread over three phases, which is needed for heavy hobs or cookers.
That depends on the power rating on your hob's rating plate. Include it with your request and we will advise which connection you need.
Lighter induction hobs sometimes work on their own cooking circuit, but more powerful models need a separate cooking circuit or Perilex to prevent overloading and a tripping circuit.
Often, yes. A cooking circuit preferably gets its own circuit. If there is no room left, we look at whether the fuse box can be extended (see adding an extra circuit) or whether a new fuse box is the better choice.
Usually 1 to 2 hours. If a cable first needs to be run to the meter cupboard, it can take a little longer.

New kitchen? Combine the work

A new kitchen often involves more than just the hob. The dishwasher, oven and fridge should be on their own circuits, and sockets sometimes need to move. If you do everything in one go, the wall only needs to be opened once. Only swapping the hob? See induction hob installation. Read more about moving sockets and adding an extra circuit, or see all prices on our prices page. We connect Perilex sockets throughout Utrecht and the surrounding area.

NEED A PERILEX OR COOKING CIRCUIT?

Request a fixed price.

Send us the rating plate of your hob or cooker and you will know the cost upfront.

Quick contact WhatsApp us Send a photo & get a price